PT without developer

For a testing procedure according to the most commonly required specifications, a developer of the approved product family has to be used.

Deviations are allowed, if the contracting partners agree. This allowance can be achieved, if the evidence can be provided, that the process without developer shows the relevant indications in the same or better way as the process with developer.

We offer suitable high performance penetrants for this special purpose and  we assist to determine the necessary adjustments of the penetrant removal process in order to achieve the desired results.

Based on our experience this developer-free process is already implemented at serveral high-volume-testing customers.

Shorter throughput times, lower costs for consumables and no subsequent part cleaning are the most importants benefits for the process.

Please, do not hesitate to ask us: We would be pleased to check your processes to determine potentials of cost reductions.